Chuyển đến nội dung chính

Máy tính hệ số U tường

Khoa học & Kỹ thuật

điện trở nhiệt lớp GB 50176

Xem nhanh kết quả

Wall U-Value Calculator: GB 50176 layered thermal resistance. Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

Wall layers

mm
mm
mm
Thermal transmittance U/K0.64 W/(m²·K)
Total resistance R₀1.57 m²·K/W
Insulation layer R1.22 m²·K/W

How it works

  1. 1Layer R = δ ÷ λ: base 0.200 ÷ 1.74 = 0.11; insulation 0.050 ÷ 0.041 = 1.22; plaster 0.040 ÷ 0.93 × 2
  2. 2R₀ = Ri 0.11 + Σ layers + Re 0.04 = 1.57 m²·K/W
  3. 3K = 1 ÷ R₀ = 1 ÷ 1.57 = 0.64 W/(m²·K)
GB 55015-2021 residential exterior wall U-value limits: severe cold ≈0.25-0.35, cold ≈0.35-0.45, hot-summer-cold-winter ≈0.8, hot-summer-warm-winter ≈1.5 W/(m²·K) - check the climate zone tables. Design λ values need material correction factors (EPS 1.05-1.2, rock wool 1.1-1.2). Thermal bridges at beams/columns raise the average U by 10-30%. Windows are usually the weak point (double glazing ≈2.5-2.8) - prioritize glazing upgrades.

Công cụ này có hữu ích cho bạn không?

Hướng dẫn sử dụng

  1. Enter known quantities: fill values and confirm units in the Wall U-Value Calculator.
  2. Instant solution: unknowns solve live with the formula shown transparently.
  3. Use constant/material tables: standard physical constants and material data are listed on this page.
  4. Compare conditions: change inputs to compare scenarios.

Điểm chính

  • Wall U-Value Calculator is a free online science & engineering tool — open and use, no sign-up.
  • All calculations run locally in your browser; your data never leaves the device.
  • Key capability: GB 50176 layered thermal resistance.
  • Results come with formulas and reference tables so you can verify every number.

Công thức và nguyên lý hoạt động

Wall U-Value Calculator formula

Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

Câu hỏi thường gặp

How do I use the Wall U-Value Calculator?
Open the page and fill in the input fields — results update automatically. GB 50176 layered thermal resistance.
Are the results accurate?
Yes. Standard formulas and conversion factors are used and verified.
Is it free? Do I need to sign up?
Completely free. No registration, login or download required.
Does it work on mobile?
Yes. The responsive design works on phones, tablets and desktops.
Is my data saved?
No. Everything runs locally in your browser.

Công cụ liên quan

Hướng dẫn liên quan

Nguồn và cập nhật

Based on CODATA recommended constants and standard physics formulas. Last updated: 2025-07

Cập nhật gần nhất:

Công thức và nội dung trên trang này đã được đội ngũ YiJianSuan kiểm tra lại, chỉ dùng để tham khảo học tập, các nghiệp vụ thực tế vui lòng tuân theo thông báo chính thức.

Nội dung được đội ngũ biên tập YiJianSuan duy trì và kiểm tra lại định kỳ, quy trình cập nhật và kiểm duyệt xem tạiQuy định biên tập.

Trích dẫn trang này: YiJianSuan. Máy tính hệ số U tường[EB/OL]. https://www.yijiansuan.com/vi/c/science/insulation-r

Kết quả do công cụ này cung cấp chỉ mang tính tham khảo, không cấu thành bất kỳ lời khuyên chuyên nghiệp nào, vui lòng dựa trên kết quả tính toán chính thức.