Lompat ke konten utama

Kalkulator Nilai-U Dinding

Sains & Teknik

Resistansi termal berlapis GB 50176

Jawaban Cepat

Wall U-Value Calculator: GB 50176 layered thermal resistance. Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

Wall layers

mm
mm
mm
Thermal transmittance U/K0.64 W/(m²·K)
Total resistance R₀1.57 m²·K/W
Insulation layer R1.22 m²·K/W

How it works

  1. 1Layer R = δ ÷ λ: base 0.200 ÷ 1.74 = 0.11; insulation 0.050 ÷ 0.041 = 1.22; plaster 0.040 ÷ 0.93 × 2
  2. 2R₀ = Ri 0.11 + Σ layers + Re 0.04 = 1.57 m²·K/W
  3. 3K = 1 ÷ R₀ = 1 ÷ 1.57 = 0.64 W/(m²·K)
GB 55015-2021 residential exterior wall U-value limits: severe cold ≈0.25-0.35, cold ≈0.35-0.45, hot-summer-cold-winter ≈0.8, hot-summer-warm-winter ≈1.5 W/(m²·K) - check the climate zone tables. Design λ values need material correction factors (EPS 1.05-1.2, rock wool 1.1-1.2). Thermal bridges at beams/columns raise the average U by 10-30%. Windows are usually the weak point (double glazing ≈2.5-2.8) - prioritize glazing upgrades.

Apakah alat ini membantu Anda?

Cara Pakai

  1. Enter known quantities: fill values and confirm units in the Wall U-Value Calculator.
  2. Instant solution: unknowns solve live with the formula shown transparently.
  3. Use constant/material tables: standard physical constants and material data are listed on this page.
  4. Compare conditions: change inputs to compare scenarios.

Poin Penting

  • Wall U-Value Calculator is a free online science & engineering tool — open and use, no sign-up.
  • All calculations run locally in your browser; your data never leaves the device.
  • Key capability: GB 50176 layered thermal resistance.
  • Results come with formulas and reference tables so you can verify every number.

Prinsip & Rumus

Wall U-Value Calculator formula

Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

FAQ

How do I use the Wall U-Value Calculator?
Open the page and fill in the input fields — results update automatically. GB 50176 layered thermal resistance.
Are the results accurate?
Yes. Standard formulas and conversion factors are used and verified.
Is it free? Do I need to sign up?
Completely free. No registration, login or download required.
Does it work on mobile?
Yes. The responsive design works on phones, tablets and desktops.
Is my data saved?
No. Everything runs locally in your browser.

Alat Terkait

Panduan terkait

Sumber & Pembaruan

Based on CODATA recommended constants and standard physics formulas. Last updated: 2025-07

Terakhir Diperbarui:

Rumus dan konten di halaman ini telah diverifikasi oleh tim YiJianSuan, hanya untuk referensi pembelajaran. Silakan merujuk ke sumber resmi untuk keperluan bisnis praktis.

Konten dikelola dan diverifikasi secara berkala oleh tim editorial YiJianSuan, proses pembaruan dan peninjauan dapat dilihat diKebijakan Editorial.

Kutip Halaman Ini: YiJianSuan. Kalkulator Nilai-U Dinding[EB/OL]. https://www.yijiansuan.com/id/c/science/insulation-r

Hasil yang diberikan oleh alat ini hanya untuk referensi dan tidak merupakan saran profesional apa pun, silakan merujuk ke perhitungan resmi.