Ana içeriğe geç

Duvar U-Değeri Hesap Makinesi

Bilim ve Mühendislik

GB 50176 katmanlı ısıl direnç

Hızlı Cevap

Wall U-Value Calculator: GB 50176 layered thermal resistance. Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

Wall layers

mm
mm
mm
Thermal transmittance U/K0.64 W/(m²·K)
Total resistance R₀1.57 m²·K/W
Insulation layer R1.22 m²·K/W

How it works

  1. 1Layer R = δ ÷ λ: base 0.200 ÷ 1.74 = 0.11; insulation 0.050 ÷ 0.041 = 1.22; plaster 0.040 ÷ 0.93 × 2
  2. 2R₀ = Ri 0.11 + Σ layers + Re 0.04 = 1.57 m²·K/W
  3. 3K = 1 ÷ R₀ = 1 ÷ 1.57 = 0.64 W/(m²·K)
GB 55015-2021 residential exterior wall U-value limits: severe cold ≈0.25-0.35, cold ≈0.35-0.45, hot-summer-cold-winter ≈0.8, hot-summer-warm-winter ≈1.5 W/(m²·K) - check the climate zone tables. Design λ values need material correction factors (EPS 1.05-1.2, rock wool 1.1-1.2). Thermal bridges at beams/columns raise the average U by 10-30%. Windows are usually the weak point (double glazing ≈2.5-2.8) - prioritize glazing upgrades.

Bu araç size yardımcı oldu mu?

Nasıl Kullanılır

  1. Enter known quantities: fill values and confirm units in the Wall U-Value Calculator.
  2. Instant solution: unknowns solve live with the formula shown transparently.
  3. Use constant/material tables: standard physical constants and material data are listed on this page.
  4. Compare conditions: change inputs to compare scenarios.

Temel Noktalar

  • Wall U-Value Calculator is a free online science & engineering tool — open and use, no sign-up.
  • All calculations run locally in your browser; your data never leaves the device.
  • Key capability: GB 50176 layered thermal resistance.
  • Results come with formulas and reference tables so you can verify every number.

Prensip ve Formüller

Wall U-Value Calculator formula

Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

SSS

How do I use the Wall U-Value Calculator?
Open the page and fill in the input fields — results update automatically. GB 50176 layered thermal resistance.
Are the results accurate?
Yes. Standard formulas and conversion factors are used and verified.
Is it free? Do I need to sign up?
Completely free. No registration, login or download required.
Does it work on mobile?
Yes. The responsive design works on phones, tablets and desktops.
Is my data saved?
No. Everything runs locally in your browser.

İlgili Araçlar

İlgili rehberler

Kaynak ve Güncellemeler

Based on CODATA recommended constants and standard physics formulas. Last updated: 2025-07

Son Güncelleme:

Bu sayfadaki formüller ve içerikler YiJianSuan ekibi tarafından gözden geçirilmiştir, sadece öğrenme amaçlı referans niteliğindedir. Gerçek işlemlerde resmi açıklamalar esas alınmalıdır.

İçerik, YiJianSuan editör ekibi tarafından korunur ve periyodik olarak gözden geçirilir, güncelleme ve denetim süreci için bakınızEditörlük Politikası.

Bu Sayfayı Alıntıla: YiJianSuan. Duvar U-Değeri Hesap Makinesi[EB/OL]. https://www.yijiansuan.com/tr/c/science/insulation-r

Bu araç tarafından sağlanan sonuçlar sadece referans amaçlıdır, hiçbir şekilde profesyonel tavsiye niteliği taşımaz, resmi hesaplamalar esas alınmalıdır.