الانتقال إلى المحتوى الرئيسي

آلة حاسبة قيمة U للجدار

العلوم والهندسة

المقاومة الحرارية الطبقية حسب GB 50176

عرض سريع للإجابة

Wall U-Value Calculator: GB 50176 layered thermal resistance. Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

Wall layers

mm
mm
mm
Thermal transmittance U/K0.64 W/(m²·K)
Total resistance R₀1.57 m²·K/W
Insulation layer R1.22 m²·K/W

How it works

  1. 1Layer R = δ ÷ λ: base 0.200 ÷ 1.74 = 0.11; insulation 0.050 ÷ 0.041 = 1.22; plaster 0.040 ÷ 0.93 × 2
  2. 2R₀ = Ri 0.11 + Σ layers + Re 0.04 = 1.57 m²·K/W
  3. 3K = 1 ÷ R₀ = 1 ÷ 1.57 = 0.64 W/(m²·K)
GB 55015-2021 residential exterior wall U-value limits: severe cold ≈0.25-0.35, cold ≈0.35-0.45, hot-summer-cold-winter ≈0.8, hot-summer-warm-winter ≈1.5 W/(m²·K) - check the climate zone tables. Design λ values need material correction factors (EPS 1.05-1.2, rock wool 1.1-1.2). Thermal bridges at beams/columns raise the average U by 10-30%. Windows are usually the weak point (double glazing ≈2.5-2.8) - prioritize glazing upgrades.

هل هذه الأداة مفيدة لك؟

كيفية الاستخدام

  1. Enter known quantities: fill values and confirm units in the Wall U-Value Calculator.
  2. Instant solution: unknowns solve live with the formula shown transparently.
  3. Use constant/material tables: standard physical constants and material data are listed on this page.
  4. Compare conditions: change inputs to compare scenarios.

النقاط الأساسية

  • Wall U-Value Calculator is a free online science & engineering tool — open and use, no sign-up.
  • All calculations run locally in your browser; your data never leaves the device.
  • Key capability: GB 50176 layered thermal resistance.
  • Results come with formulas and reference tables so you can verify every number.

المبادئ والمعادلات

Wall U-Value Calculator formula

Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

الأسئلة الشائعة

How do I use the Wall U-Value Calculator?
Open the page and fill in the input fields — results update automatically. GB 50176 layered thermal resistance.
Are the results accurate?
Yes. Standard formulas and conversion factors are used and verified.
Is it free? Do I need to sign up?
Completely free. No registration, login or download required.
Does it work on mobile?
Yes. The responsive design works on phones, tablets and desktops.
Is my data saved?
No. Everything runs locally in your browser.

الأدوات ذات الصلة

تصفح كل 105 أداة في هذه الفئة →

أدلة ذات صلة

المصدر والتحديثات

Based on CODATA recommended constants and standard physics formulas. Last updated: 2025-07

آخر تحديث:

تم مراجعة المعادلات والمحتويات في هذه الصفحة من قبل فريق YiJianSuan، وهي للمرجع التعليمي فقط. يرجى الاعتماد على المصادر الرسمية في العمليات الفعلية.

يتم صيانة المحتوى ومراجعته بشكل دوري من قبل فريق التحرير في YiJianSuan، ويمكن الاطلاع على عمليات التحديث والمراجعة فيالسياسات التحريرية.

استشهد بهذه الصفحة: YiJianSuan. آلة حاسبة قيمة U للجدار[EB/OL]. https://www.yijiansuan.com/ar/c/science/insulation-r

النتائج التي يقدمها هذا الأداة للمرجع فقط ولا تشكل أي نصيحة مهنية، يرجى الاعتماد على الحسابات الرسمية.