Lompat ke kandungan utama

Kalkulator Nilai-U Dinding

Sains & Kejuruteraan

Rintangan haba berlapis GB 50176

Jawapan Pantas

Wall U-Value Calculator: GB 50176 layered thermal resistance. Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

Wall layers

mm
mm
mm
Thermal transmittance U/K0.64 W/(m²·K)
Total resistance R₀1.57 m²·K/W
Insulation layer R1.22 m²·K/W

How it works

  1. 1Layer R = δ ÷ λ: base 0.200 ÷ 1.74 = 0.11; insulation 0.050 ÷ 0.041 = 1.22; plaster 0.040 ÷ 0.93 × 2
  2. 2R₀ = Ri 0.11 + Σ layers + Re 0.04 = 1.57 m²·K/W
  3. 3K = 1 ÷ R₀ = 1 ÷ 1.57 = 0.64 W/(m²·K)
GB 55015-2021 residential exterior wall U-value limits: severe cold ≈0.25-0.35, cold ≈0.35-0.45, hot-summer-cold-winter ≈0.8, hot-summer-warm-winter ≈1.5 W/(m²·K) - check the climate zone tables. Design λ values need material correction factors (EPS 1.05-1.2, rock wool 1.1-1.2). Thermal bridges at beams/columns raise the average U by 10-30%. Windows are usually the weak point (double glazing ≈2.5-2.8) - prioritize glazing upgrades.

Adakah alat ini membantu anda?

Cara Guna

  1. Enter known quantities: fill values and confirm units in the Wall U-Value Calculator.
  2. Instant solution: unknowns solve live with the formula shown transparently.
  3. Use constant/material tables: standard physical constants and material data are listed on this page.
  4. Compare conditions: change inputs to compare scenarios.

Perkara Utama

  • Wall U-Value Calculator is a free online science & engineering tool — open and use, no sign-up.
  • All calculations run locally in your browser; your data never leaves the device.
  • Key capability: GB 50176 layered thermal resistance.
  • Results come with formulas and reference tables so you can verify every number.

Prinsip & Formula

Wall U-Value Calculator formula

Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

Soalan Lazim

How do I use the Wall U-Value Calculator?
Open the page and fill in the input fields — results update automatically. GB 50176 layered thermal resistance.
Are the results accurate?
Yes. Standard formulas and conversion factors are used and verified.
Is it free? Do I need to sign up?
Completely free. No registration, login or download required.
Does it work on mobile?
Yes. The responsive design works on phones, tablets and desktops.
Is my data saved?
No. Everything runs locally in your browser.

Alat Berkaitan

Panduan berkaitan

Sumber & Kemas Kini

Based on CODATA recommended constants and standard physics formulas. Last updated: 2025-07

Kemas Kini Terkini:

Formula dan kandungan di halaman ini telah disemak semula oleh pasukan YiJianSuan, hanya untuk rujukan pembelajaran — sila rujuk sumber rasmi untuk urusan sebenar.

Kandungan diselenggara dan disemak semula secara berkala oleh pasukan editorial YiJianSuan — proses kemas kini dan semakan boleh dilihat diDasar Editorial.

Petik Halaman Ini: YiJianSuan. Kalkulator Nilai-U Dinding[EB/OL]. https://www.yijiansuan.com/ms/c/science/insulation-r

Keputusan yang diberikan oleh alat ini hanyalah untuk rujukan, tidak membentuk sebarang nasihat profesional — sila rujuk pengiraan rasmi.