Zum Hauptinhalt springen

Wand-U-Wert-Rechner

Wissenschaft & Technik

GB 50176 schichtweiser Wärmewiderstand

Schnellantwort

Wall U-Value Calculator: GB 50176 layered thermal resistance. Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

Wall layers

mm
mm
mm
Thermal transmittance U/K0.64 W/(m²·K)
Total resistance R₀1.57 m²·K/W
Insulation layer R1.22 m²·K/W

How it works

  1. 1Layer R = δ ÷ λ: base 0.200 ÷ 1.74 = 0.11; insulation 0.050 ÷ 0.041 = 1.22; plaster 0.040 ÷ 0.93 × 2
  2. 2R₀ = Ri 0.11 + Σ layers + Re 0.04 = 1.57 m²·K/W
  3. 3K = 1 ÷ R₀ = 1 ÷ 1.57 = 0.64 W/(m²·K)
GB 55015-2021 residential exterior wall U-value limits: severe cold ≈0.25-0.35, cold ≈0.35-0.45, hot-summer-cold-winter ≈0.8, hot-summer-warm-winter ≈1.5 W/(m²·K) - check the climate zone tables. Design λ values need material correction factors (EPS 1.05-1.2, rock wool 1.1-1.2). Thermal bridges at beams/columns raise the average U by 10-30%. Windows are usually the weak point (double glazing ≈2.5-2.8) - prioritize glazing upgrades.

Ist dieses Tool für Sie hilfreich?

Anleitung

  1. Enter known quantities: fill values and confirm units in the Wall U-Value Calculator.
  2. Instant solution: unknowns solve live with the formula shown transparently.
  3. Use constant/material tables: standard physical constants and material data are listed on this page.
  4. Compare conditions: change inputs to compare scenarios.

Kernpunkte

  • Wall U-Value Calculator is a free online science & engineering tool — open and use, no sign-up.
  • All calculations run locally in your browser; your data never leaves the device.
  • Key capability: GB 50176 layered thermal resistance.
  • Results come with formulas and reference tables so you can verify every number.

Prinzip & Formeln

Wall U-Value Calculator formula

Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

FAQ

How do I use the Wall U-Value Calculator?
Open the page and fill in the input fields — results update automatically. GB 50176 layered thermal resistance.
Are the results accurate?
Yes. Standard formulas and conversion factors are used and verified.
Is it free? Do I need to sign up?
Completely free. No registration, login or download required.
Does it work on mobile?
Yes. The responsive design works on phones, tablets and desktops.
Is my data saved?
No. Everything runs locally in your browser.

Verwandte Tools

Verwandte Anleitungen

Quellen & Aktualisierungen

Based on CODATA recommended constants and standard physics formulas. Last updated: 2025-07

Zuletzt aktualisiert:

Formeln und Inhalte dieser Seite wurden vom YiJianSuan-Team überprüft. Sie dienen nur als Lernreferenz – für praktische Angelegenheiten gelten die offiziellen Angaben.

Inhalte werden vom YiJianSuan-Redaktionsteam gepflegt und regelmäßig überprüft. Der Aktualisierungs- und Prüfprozess ist einsehbar unterRedaktionsrichtlinie.

Seite zitieren: YiJianSuan. Wand-U-Wert-Rechner[EB/OL]. https://www.yijiansuan.com/de/c/science/insulation-r

Die mit diesem Tool erzielten Ergebnisse dienen nur als Referenz und stellen keine professionelle Beratung dar. Bitte orientieren Sie sich an der offiziellen Berechnung.