Vai al contenuto principale

Calcolatrice Valore U Parete

Scienza e Ingegneria

Resistenza termica stratificata GB 50176

Panoramica rapida delle risposte

Wall U-Value Calculator: GB 50176 layered thermal resistance. Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

Wall layers

mm
mm
mm
Thermal transmittance U/K0.64 W/(m²·K)
Total resistance R₀1.57 m²·K/W
Insulation layer R1.22 m²·K/W

How it works

  1. 1Layer R = δ ÷ λ: base 0.200 ÷ 1.74 = 0.11; insulation 0.050 ÷ 0.041 = 1.22; plaster 0.040 ÷ 0.93 × 2
  2. 2R₀ = Ri 0.11 + Σ layers + Re 0.04 = 1.57 m²·K/W
  3. 3K = 1 ÷ R₀ = 1 ÷ 1.57 = 0.64 W/(m²·K)
GB 55015-2021 residential exterior wall U-value limits: severe cold ≈0.25-0.35, cold ≈0.35-0.45, hot-summer-cold-winter ≈0.8, hot-summer-warm-winter ≈1.5 W/(m²·K) - check the climate zone tables. Design λ values need material correction factors (EPS 1.05-1.2, rock wool 1.1-1.2). Thermal bridges at beams/columns raise the average U by 10-30%. Windows are usually the weak point (double glazing ≈2.5-2.8) - prioritize glazing upgrades.

Questo strumento ti è stato utile?

Come usare

  1. Enter known quantities: fill values and confirm units in the Wall U-Value Calculator.
  2. Instant solution: unknowns solve live with the formula shown transparently.
  3. Use constant/material tables: standard physical constants and material data are listed on this page.
  4. Compare conditions: change inputs to compare scenarios.

Punti chiave

  • Wall U-Value Calculator is a free online science & engineering tool — open and use, no sign-up.
  • All calculations run locally in your browser; your data never leaves the device.
  • Key capability: GB 50176 layered thermal resistance.
  • Results come with formulas and reference tables so you can verify every number.

Principi e formule

Wall U-Value Calculator formula

Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

Domande frequenti

How do I use the Wall U-Value Calculator?
Open the page and fill in the input fields — results update automatically. GB 50176 layered thermal resistance.
Are the results accurate?
Yes. Standard formulas and conversion factors are used and verified.
Is it free? Do I need to sign up?
Completely free. No registration, login or download required.
Does it work on mobile?
Yes. The responsive design works on phones, tablets and desktops.
Is my data saved?
No. Everything runs locally in your browser.

Strumenti correlati

Guide correlate

Fonti e aggiornamenti

Based on CODATA recommended constants and standard physics formulas. Last updated: 2025-07

Ultimo aggiornamento:

Le formule e i contenuti di questa pagina sono stati verificati dal team di YiJianSuan. Sono solo per riferimento di studio: per le operazioni effettive, si prega di attenersi alle indicazioni ufficiali.

I contenuti sono mantenuti e periodicamente verificati dal team editoriale di YiJianSuan. Il processo di aggiornamento e verifica è disponibile aNorme editoriali.

Cita questa pagina: YiJianSuan. Calcolatrice Valore U Parete[EB/OL]. https://www.yijiansuan.com/it/c/science/insulation-r

I risultati forniti da questo strumento sono solo per riferimento e non costituiscono alcun consiglio professionale: si prega di attenersi ai calcoli ufficiali.