Saltar al contenido principal

Calculadora de Valor U de Pared

Ciencia e Ingeniería

Resistencia térmica por capas GB 50176

Respuesta rápida

Wall U-Value Calculator: GB 50176 layered thermal resistance. Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

Wall layers

mm
mm
mm
Thermal transmittance U/K0.64 W/(m²·K)
Total resistance R₀1.57 m²·K/W
Insulation layer R1.22 m²·K/W

How it works

  1. 1Layer R = δ ÷ λ: base 0.200 ÷ 1.74 = 0.11; insulation 0.050 ÷ 0.041 = 1.22; plaster 0.040 ÷ 0.93 × 2
  2. 2R₀ = Ri 0.11 + Σ layers + Re 0.04 = 1.57 m²·K/W
  3. 3K = 1 ÷ R₀ = 1 ÷ 1.57 = 0.64 W/(m²·K)
GB 55015-2021 residential exterior wall U-value limits: severe cold ≈0.25-0.35, cold ≈0.35-0.45, hot-summer-cold-winter ≈0.8, hot-summer-warm-winter ≈1.5 W/(m²·K) - check the climate zone tables. Design λ values need material correction factors (EPS 1.05-1.2, rock wool 1.1-1.2). Thermal bridges at beams/columns raise the average U by 10-30%. Windows are usually the weak point (double glazing ≈2.5-2.8) - prioritize glazing upgrades.

¿Te ha sido útil esta herramienta?

Cómo usar

  1. Enter known quantities: fill values and confirm units in the Wall U-Value Calculator.
  2. Instant solution: unknowns solve live with the formula shown transparently.
  3. Use constant/material tables: standard physical constants and material data are listed on this page.
  4. Compare conditions: change inputs to compare scenarios.

Puntos clave

  • Wall U-Value Calculator is a free online science & engineering tool — open and use, no sign-up.
  • All calculations run locally in your browser; your data never leaves the device.
  • Key capability: GB 50176 layered thermal resistance.
  • Results come with formulas and reference tables so you can verify every number.

Principios y fórmulas

Wall U-Value Calculator formula

Wall U-Value Calculator uses standard science & engineering formulas to compute accurate results instantly.

Preguntas frecuentes

How do I use the Wall U-Value Calculator?
Open the page and fill in the input fields — results update automatically. GB 50176 layered thermal resistance.
Are the results accurate?
Yes. Standard formulas and conversion factors are used and verified.
Is it free? Do I need to sign up?
Completely free. No registration, login or download required.
Does it work on mobile?
Yes. The responsive design works on phones, tablets and desktops.
Is my data saved?
No. Everything runs locally in your browser.

Herramientas relacionadas

Guías relacionadas

Fuente y actualizaciones

Based on CODATA recommended constants and standard physics formulas. Last updated: 2025-07

Última actualización:

Las fórmulas y el contenido de esta página han sido revisados por el equipo de YiJianSuan. Son solo para fines de aprendizaje y referencia; para asuntos prácticos, consulte la información oficial.

El contenido es mantenido y revisado periódicamente por el equipo editorial de YiJianSuan. El proceso de actualización y revisión se puede consultar enPolítica editorial.

Citar esta página: YiJianSuan. Calculadora de Valor U de Pared[EB/OL]. https://www.yijiansuan.com/es/c/science/insulation-r

Los resultados proporcionados por esta herramienta son solo para referencia y no constituyen ningún consejo profesional. Consulte el cálculo oficial para confirmar.