Ir para o conteúdo principal

AWG Bitola de Fio: AWG → mm² Conversor

Conversores de Unidades

AWG para mm², diâmetro, capacidade de corrente

Resposta Rápida

AWG Wire Gauge Converter: AWG to mm², diameter, ampacity. AWG Wire Gauge Converter uses standard unit conversion formulas to compute accurate results instantly.

AWG Correspondente18
Diâmetro do Condutor1.024mm
Área da Seção Transversal0.823mm²
Estimativa de corrente (fio de cobre em tubo)4A
Resistência por metro20.90mΩ/m
Queda de tensão de ida e volta2.09V
Proporção de queda de tensão em 220V0.95%
Potência de perda de linha10.45W

Etapas de Cálculo

  1. 1Diâmetro do condutor: d = 0,127 × 92^((36−18)/39) = 1.024 mm
  2. 2Cross-section: A = πd²/4 = 0.823 mm²; ampacity ≈ 5 A/mm² → 4 A (conservative, in conduit)
  3. 3Resistência por metro: R = ρ/A = 0.0172 ÷ 0.823 = 20.90 mΩ/m
  4. 4Round-trip drop: V = I × R × 2L = 5 × 20.90mΩ × 20 = 2.09 V (0.95% of 220V)

Tabela de consulta rápida de bitola de fio comum AWG

AWGDiâmetro (mm)Área da Seção Transversal (mm²)Capacidade de corrente (A)
102.5885.26126
122.0533.30917
141.6282.08110
161.2911.3097
181.0240.8234
200.8120.5183
220.6440.3262
240.5110.2051
260.4050.1291
280.3210.0810
300.2550.0510
AWG a cada diferença de 3 números, área de seção transversal reduzida pela metade/dobrada. Estime corrente de fio de cobre em tubulação conservadoramente em 5A/mm², instalação aérea exposta pode chegar a 2 vezes. Quando queda de tensão excede 3% (sistema 220V) ou 5% (sistema de baixa tensão 12V), deve aumentar diâmetro do fio.

Esta ferramenta foi útil para você?

Como Usar

  1. Pick units: switch source and target units in the AWG Wire Gauge Converter.
  2. Enter a value: results sync both ways instantly — no convert button needed.
  3. Use the reference table: common conversions are listed for instant lookup.
  4. Copy the result: copy the converted value with its unit.

Pontos Principais

  • AWG Wire Gauge Converter is a free online unit conversion tool — open and use, no sign-up.
  • All calculations run locally in your browser; your data never leaves the device.
  • Key capability: AWG to mm², diameter, ampacity.
  • Results come with formulas and reference tables so you can verify every number.

Fórmulas e Funcionamento

AWG Wire Gauge Converter formula

AWG Wire Gauge Converter uses standard unit conversion formulas to compute accurate results instantly.

Perguntas Frequentes

How do I use the AWG Wire Gauge Converter?
Open the page and fill in the input fields — results update automatically. AWG to mm², diameter, ampacity.
Are the results accurate?
Yes. Standard formulas and conversion factors are used and verified.
Is it free? Do I need to sign up?
Completely free. No registration, login or download required.
Does it work on mobile?
Yes. The responsive design works on phones, tablets and desktops.
Is my data saved?
No. Everything runs locally in your browser.

Ferramentas Relacionadas

Guias relacionados

Fonte e Atualizações

Based on SI conversion factors and international standards. Last updated: 2025-07

Fontes Autorizadas:

Última Atualização:

As fórmulas e o conteúdo desta página foram revisados pela equipe YiJianSuan. São apenas para referência de aprendizado — consulte as fontes oficiais para assuntos práticos.

Mantido e revisado periodicamente pela equipe editorial YiJianSuan — o processo de atualização e revisão está disponível emPolítica Editorial.

Citar esta Página: YiJianSuan. AWG Bitola de Fio: AWG → mm² Conversor[EB/OL]. https://www.yijiansuan.com/pt/c/convert/awg-wire

Os resultados fornecidos por esta ferramenta são apenas para referência e não constituem aconselhamento profissional. Consulte os cálculos oficiais para confirmação.