Aller au contenu principal

Convertisseur de calibre de fil AWG

Convertisseurs d'Unités

AWG vers mm², diamètre, ampacité

Aperçu rapide du résultat

AWG Wire Gauge Converter: AWG to mm², diameter, ampacity. AWG Wire Gauge Converter uses standard unit conversion formulas to compute accurate results instantly.

AWG correspondant18
Diamètre du conducteur1.024mm
Section transversale0.823mm²
Estimation du courant admissible (fil de cuivre dans le tube)4A
Résistance par mètre20.90mΩ/m
Chute de tension aller-retour2.09V
Pourcentage de chute de tension sous 220V0.95%
Puissance de perte de ligne10.45W

Étapes de calcul

  1. 1Diamètre du conducteur : d = 0,127 × 92^((36−18)/39) = 1.024 mm
  2. 2Cross-section: A = πd²/4 = 0.823 mm²; ampacity ≈ 5 A/mm² → 4 A (conservative, in conduit)
  3. 3Résistance par mètre : R = ρ/A = 0.0172 ÷ 0.823 = 20.90 mΩ/m
  4. 4Round-trip drop: V = I × R × 2L = 5 × 20.90mΩ × 20 = 2.09 V (0.95% of 220V)

Tableau de référence des calibres de fil AWG

AWGDiamètre (mm)Section transversale (mm²)Courant admissible (A)
102.5885.26126
122.0533.30917
141.6282.08110
161.2911.3097
181.0240.8234
200.8120.5183
220.6440.3262
240.5110.2051
260.4050.1291
280.3210.0810
300.2550.0510
Chaque différence de 3 numéros AWG, la section transversale double ou diminue de moitié. Estimez le courant admissible à 5A/mm² pour fil de cuisson en tube, pour fil posé à l'air libre, il peut atteindre 2 fois. Si la chute de tension dépasse 3% (système 220V) ou 5% (système basse tension 12V), augmentez le diamètre du fil.

Cet outil vous a-t-il été utile ?

Mode d'emploi

  1. Pick units: switch source and target units in the AWG Wire Gauge Converter.
  2. Enter a value: results sync both ways instantly — no convert button needed.
  3. Use the reference table: common conversions are listed for instant lookup.
  4. Copy the result: copy the converted value with its unit.

Points clés

  • AWG Wire Gauge Converter is a free online unit conversion tool — open and use, no sign-up.
  • All calculations run locally in your browser; your data never leaves the device.
  • Key capability: AWG to mm², diameter, ampacity.
  • Results come with formulas and reference tables so you can verify every number.

Principes et formules

AWG Wire Gauge Converter formula

AWG Wire Gauge Converter uses standard unit conversion formulas to compute accurate results instantly.

FAQ

How do I use the AWG Wire Gauge Converter?
Open the page and fill in the input fields — results update automatically. AWG to mm², diameter, ampacity.
Are the results accurate?
Yes. Standard formulas and conversion factors are used and verified.
Is it free? Do I need to sign up?
Completely free. No registration, login or download required.
Does it work on mobile?
Yes. The responsive design works on phones, tablets and desktops.
Is my data saved?
No. Everything runs locally in your browser.

Outils associés

Guides associés

Sources et mises à jour

Based on SI conversion factors and international standards. Last updated: 2025-07

Sources officielles:

Dernière mise à jour:

Les formules et contenus de cette page ont été vérifiés par l'équipe YiJianSuan. Ils sont fournis à titre informatif uniquement — les sources officielles font foi.

Contenu maintenu et vérifié périodiquement par l'équipe éditoriale YiJianSuan — la procédure de mise à jour et de validation est disponible surRègles éditoriales.

Citer cette page: YiJianSuan. Convertisseur de calibre de fil AWG[EB/OL]. https://www.yijiansuan.com/fr/c/convert/awg-wire

Les résultats fournis par cet outil sont donnés à titre indicatif uniquement et ne constituent aucun conseil professionnel. Référez-vous aux calculs officiels.