Saltar al contenido principal

Convertidor de Calibre de Alambre AWG

Convertidores de Unidades

AWG a mm², diámetro, capacidad de corriente

Respuesta rápida

AWG Wire Gauge Converter: AWG to mm², diameter, ampacity. AWG Wire Gauge Converter uses standard unit conversion formulas to compute accurate results instantly.

AWG correspondiente18
Diámetro del conductor1.024mm
Área de sección transversal0.823mm²
Estimación de corriente admisible (cable de cobre en tubería)4A
Resistencia por metro20.90mΩ/m
Caída de presión de ida y vuelta2.09V
Porcentaje caída de tensión a 220V0.95%
Potencia de pérdida de línea10.45W

Pasos de cálculo

  1. 1Diámetro del conductor: d = 0,127 × 92^((36−18)/39) = 1.024 mm
  2. 2Cross-section: A = πd²/4 = 0.823 mm²; ampacity ≈ 5 A/mm² → 4 A (conservative, in conduit)
  3. 3Resistencia por metro: R = ρ/A = 0.0172 ÷ 0.823 = 20.90 mΩ/m
  4. 4Round-trip drop: V = I × R × 2L = 5 × 20.90mΩ × 20 = 2.09 V (0.95% of 220V)

Tabla rápida calibres cable AWG comunes

AWGDiámetro (mm)Área de sección (mm²)Corriente admisible (A)
102.5885.26126
122.0533.30917
141.6282.08110
161.2911.3097
181.0240.8234
200.8120.5183
220.6440.3262
240.5110.2051
260.4050.1291
280.3210.0810
300.2550.0510
Cada 3 números AWG, sección transversal se reduce a la mitad o duplica. Estimar capacidad corriente conservadoramente 5A/mm² para cable de cobre en tubería, instalación aérea abierta alcanza 2 veces. Si caída de tensión supera 3% (sistema 220V) o 5% (sistema baja tensión 12V), debe aumentar diámetro cable.

¿Te ha sido útil esta herramienta?

Cómo usar

  1. Pick units: switch source and target units in the AWG Wire Gauge Converter.
  2. Enter a value: results sync both ways instantly — no convert button needed.
  3. Use the reference table: common conversions are listed for instant lookup.
  4. Copy the result: copy the converted value with its unit.

Puntos clave

  • AWG Wire Gauge Converter is a free online unit conversion tool — open and use, no sign-up.
  • All calculations run locally in your browser; your data never leaves the device.
  • Key capability: AWG to mm², diameter, ampacity.
  • Results come with formulas and reference tables so you can verify every number.

Principios y fórmulas

AWG Wire Gauge Converter formula

AWG Wire Gauge Converter uses standard unit conversion formulas to compute accurate results instantly.

Preguntas frecuentes

How do I use the AWG Wire Gauge Converter?
Open the page and fill in the input fields — results update automatically. AWG to mm², diameter, ampacity.
Are the results accurate?
Yes. Standard formulas and conversion factors are used and verified.
Is it free? Do I need to sign up?
Completely free. No registration, login or download required.
Does it work on mobile?
Yes. The responsive design works on phones, tablets and desktops.
Is my data saved?
No. Everything runs locally in your browser.

Herramientas relacionadas

Guías relacionadas

Fuente y actualizaciones

Based on SI conversion factors and international standards. Last updated: 2025-07

Fuentes autorizadas:

Última actualización:

Las fórmulas y el contenido de esta página han sido revisados por el equipo de YiJianSuan. Son solo para fines de aprendizaje y referencia; para asuntos prácticos, consulte la información oficial.

El contenido es mantenido y revisado periódicamente por el equipo editorial de YiJianSuan. El proceso de actualización y revisión se puede consultar enPolítica editorial.

Citar esta página: YiJianSuan. Convertidor de Calibre de Alambre AWG[EB/OL]. https://www.yijiansuan.com/es/c/convert/awg-wire

Los resultados proporcionados por esta herramienta son solo para referencia y no constituyen ningún consejo profesional. Consulte el cálculo oficial para confirmar.